@article{Bustillos Yaguana_Idrovo Vintimilla_2016, title={Analysis of indoor environment of a housing contemporary in the rural area of Cuenca}, volume={3}, url={https://publicaciones.ucuenca.edu.ec/ojs/index.php/estoa/article/view/617}, DOI={10.18537/10.18537/est.v003.n005.02}, abstractNote={<p><span lang="EN-US">This document seeks to make a technical calculation and analysis to verify the conditions of thermal insulation of a house chosen haphazardly, located in the rural parish of Sayausi, in the sector of Gallo Cantana, of the city of Cuenca in Ecuador, to 2800 m.a.s.l., and verify the compliance of the thermal regulation that sets Ecuadorian construction standard nec-11, according to the climate and microclimate of the town.</span></p><p><span lang="EN-US">We will make an analysis of the thermal insulation, solar protection, ventilation and natural lighting, to subsequently verify its compliance and propose, for each instance, solutions to improve them.</span></p><p><strong><span lang="EN-US">Keywords:</span></strong><span lang="EN-US"> Housing, environment, rural, Cuenca, Ecuador.</span></p>}, number={5}, journal={Estoa. Journal of the Faculty of Architecture and Urbanism}, author={Bustillos Yaguana, David and Idrovo Vintimilla, Daniel}, year={2016}, month={Mar.}, pages={9–19} }